4C-D (4-Chloromethcathinone) – Research Chemical Cathinone Derivant
Descripción del producto
Nuestra 4C-D (4-Chloromethcathinone) is a high-purity research chemical from the cathinone class, specifically developed for forensic and pharmacological research . This compound is supplied as a white crystalline powder with excellent solubility for laboratory applications.
Key Features:
✔ ≥98% Purity (GC-MS confirmado)
✔ Good solubility in water and organic solvents
✔ Stable crystalline form
✔ For scientific use only
Informe de laboratorio (COA) Resumen
*Batch #4CD-NL0325 | Tested by ForensicChem EU*
✔ 98.5% Purity (GC-MS)
✔ <0.5% Isomeric impurities
✔ No heavy metals or solvent residues
✔ HPLC analysis available upon request
Propósitos de investigación recomendados
1. Forensic Analysis
Reference standard for drug testing
Mass spectrometry identification
2. Neuropharmacological Research
Dopamine/noradrenaline reuptake inhibition
Comparative studies with related cathinones
3. Behavioral studies
Locomotor activity models (in controlled settings)
Protocolo de uso para investigadores
Preparación de la solución
Utilice physiological saline (0.9% NaCl) for water solutions
Working concentration: 1-5mg/ml for most applications
Adjust pH to 5.5-6.5 for optimal stability
Pautas de dosificación (in vitro)
Concentración inicial: 0.1mg/ml
Maximum concentration: 10mg/ml
Incubation time: ≤8 hours for neuronal cultures
Riesgos y medidas de seguridad
⚠ Cardiovascular Risks
Possible increase in heart rate and blood pressure
⚠ Neurotoxic Potential
Evitar la exposición prolongada
⚠ Situación jurídica
Fall under the Ley del Opio in the Netherlands
⚠ Storage conditions
Tienda en 4°C en un recipiente hermético.
Preguntas más frecuentes (FAQ)
Q: How does 4C-D compare to 4-CMC?
| Parámetro | 4C-D | 4-CMC |
|---|---|---|
| Posible | ★★☆ | ★★★☆ |
| Duración de la acción | 2-3 hours | 3-4 hours |
| Selectividad | NE > DA | DA > NE |
Q: Is this suitable for HPLC calibration?
A: Sí – Retention time ≈7.5 min at standard conditions
Q: Can this be used in receptor binding studies?
A: Limited – Suitable for DAT/NET research, less so for SERT
P: ¿Qué ocurre si hay contacto con la piel?
A: Wash immediately with soap and water + medical evaluation if irritation occurs
Harm Reduction for Laboratories
• Trabaje siempre bajo una campana extractora
• Wear appropriate PPE (lab coat, safety glasses, gloves)
• Keep an emergency shower available
*Disclaimer: For legally permitted scientific research only. Not for human use. 21+ only. Store in a locked cabinet.*












