4C-D (4-Chloromethcathinone) – Research Chemical Cathinone Derivant
Descripción del producto
Nuestra 4C-D (4-Chloromethcathinone) is a high-purity research chemical from the cathinone class, specifically developed for forensic and pharmacological research . This compound is supplied as a white crystalline powder with excellent solubility for laboratory applications.
Características principales:
✔ ≥98% Purity (GC-MS confirmado)
✔ Good solubility in water and organic solvents
✔ Stable crystalline form
✔ For scientific use only
Informe de laboratorio (COA) Resumen
*Batch #4CD-NL0325 | Tested by ForensicChem EU*
✔ 98.5% Purity (GC-MS)
✔ <0.5% Isomeric impurities
✔ No heavy metals or solvent residues
✔ HPLC analysis available upon request
Propósitos de investigación recomendados
1. Forensic Analysis
Reference standard for drug testing
Mass spectrometry identification
2. Neuropharmacological Research
Dopamine/noradrenaline reuptake inhibition
Comparative studies with related cathinones
3. Behavioral studies
Locomotor activity models (in controlled settings)
Protocolo de uso para investigadores
Preparación de la solución
Utilice solución salina fisiológica (0.9% NaCl) for water solutions
Working concentration: 1-5mg/ml for most applications
Adjust pH to 5.5-6.5 for optimal stability
Pautas de dosificación (in vitro)
Concentración inicial: 0.1mg/ml
Maximum concentration: 10mg/ml
Incubation time: ≤8 hours for neuronal cultures
Riesgos y medidas de seguridad
⚠ Cardiovascular Risks
Possible increase in heart rate and blood pressure
⚠ Neurotoxic Potential
Evitar la exposición prolongada
⚠ Situación jurídica
Fall under the Ley del Opio in the Netherlands
⚠ Condiciones de almacenamiento
Tienda en 4°C en un recipiente hermético.
Preguntas más frecuentes (FAQ)
Q: How does 4C-D compare to 4-CMC?
| Parámetro | 4C-D | 4-CMC |
|---|---|---|
| Posible | ★★☆ | ★★★☆ |
| Duración de la acción | 2-3 hours | 3-4 hours |
| Selectividad | NE > DA | DA > NE |
Q: Is this suitable for HPLC calibration?
A: Sí – Retention time ≈7.5 min at standard conditions
Q: Can this be used in receptor binding studies?
A: Limited – Suitable for DAT/NET research, less so for SERT
P: ¿Qué ocurre si hay contacto con la piel?
A: Wash immediately with soap and water + medical evaluation if irritation occurs
Harm Reduction for Laboratories
• Trabaje siempre bajo una campana extractora
• Wear appropriate PPE (lab coat, safety glasses, gloves)
• Keep an emergency shower available
*Disclaimer: For legally permitted scientific research only. Not for human use. 21+ only. Store in a locked cabinet.*












